Special precautions for disposal and other handling: VENBIG must be brought to room or body temperature before use.
Total reconstitution must be obtained within 30 minutes.
Reconstitution of the solution, 500 IU vial: 1. Draw the solvent into the injection syringe.
2. Inject the solvent with the same syringe into the vial containing the lyophilised substance.
3. Shake gently until solubilisation is complete.
4. Draw the solution thus obtained into the syringe.
5. Change the needle and infuse to the patient.
The solution must be clear or slightly opalescent.
Do not use solutions that are cloudy or have deposits.
Reconstituted products must be inspected visually for particulate matter and discoloration prior to administration.
After reconstitution, the product is a clear or slightly opalescent, colourless or pale yellow liquid.
Any unused product or waste material should be disposed of in accordance with local requirements.
Incompatibilities: This medicinal product must not be mixed with other medicinal products except the solvent mentioned in the previous text.